Water Ingress Mapping & Moisture Analysis
Professional water ingress mapping and moisture pathway analysis using advanced detection technology. Comprehensive identification of water entry points, moisture migration routes, and saturation level mapping for building envelope water intrusion issues across British Columbia.
Advanced Mapping Capabilities
Moisture Source Identification
Precise identification of water entry points and primary moisture sources in building systems
Pathway Tracing
Detailed mapping of water migration pathways through building materials and assemblies
Saturation Level Mapping
Quantitative measurement and mapping of moisture saturation levels in affected materials
Drying Progress Monitoring
Ongoing monitoring of moisture levels during remediation and drying processes
Comprehensive Water Ingress Analysis
Mapping of water entry through building envelope systems from exterior sources
Moisture Sources
- Roof membrane failures
- Wall cladding penetrations
- Window and door seal failures
- Foundation water intrusion
Detection Indicators
- Thermal imaging patterns
- Moisture meter readings
- Visual staining patterns
- Material degradation signs
Applications
- Storm damage assessment
- Warranty investigations
- Insurance claims
- Preventive maintenance
Exterior Water Intrusion
Professional Analysis
Analysis of moisture movement within building assemblies and interior spaces
Moisture Sources
- Plumbing system leaks
- HVAC condensation issues
- Interior humidity problems
- Vapor barrier failures
Detection Indicators
- Humidity level variations
- Condensation patterns
- Material moisture content
- Air quality measurements
Applications
- Indoor air quality issues
- Mold investigation
- HVAC system problems
- Building performance
Interior Moisture Migration
Professional Analysis
Assessment of water damage impact on structural building components
Moisture Sources
- Structural leak penetration
- Foundation water issues
- Structural connection failures
- Load-bearing element exposure
Detection Indicators
- Structural moisture levels
- Material strength degradation
- Connection corrosion
- Load capacity impacts
Applications
- Structural assessments
- Safety evaluations
- Repair planning
- Engineering analysis
Structural Water Damage
Professional Analysis
Advanced Detection Technologies
FLIR thermal cameras detect moisture through temperature variations and evaporation cooling
- Non-contact moisture detection
- Large area scanning capability
- Real-time moisture visualization
- Historical comparison analysis
Calibrated resistance and capacitance meters provide quantitative moisture measurements
- Pin-type penetrating measurements
- Non-invasive scanning measurements
- Material-specific calibration
- Data logging and trending
Precision humidity measurement for ambient and in-wall moisture conditions
- Relative humidity measurement
- Dew point calculation
- Vapor pressure analysis
- Environmental monitoring
Specialized gas testing to track air and moisture movement pathways
- Air pathway identification
- Pressure relationship mapping
- Infiltration route tracing
- Ventilation effectiveness
Water Ingress Mapping Process
Initial Assessment
Comprehensive evaluation of visible moisture damage and client-reported issues
Activities
- Visual inspection of affected areas
- Documentation of damage patterns
- Client interview and history review
- Environmental condition assessment
Deliverables
- Initial damage assessment
- Testing plan development
- Equipment selection
Moisture Detection Survey
Systematic moisture detection using thermal imaging and moisture meters
Activities
- Thermal imaging of all affected areas
- Moisture meter grid measurements
- Hidden moisture investigation
- Comparative analysis with dry areas
Deliverables
- Moisture detection maps
- Quantitative measurements
- Thermal imaging documentation
Source Identification
Detailed investigation to identify primary and secondary moisture sources
Activities
- Exterior envelope inspection
- Interior system evaluation
- Water testing procedures
- Pathway tracing analysis
Deliverables
- Source identification report
- Entry point documentation
- Pathway analysis
Migration Pathway Mapping
Comprehensive mapping of water migration routes through building assemblies
Activities
- Material moisture profiling
- Assembly moisture mapping
- Gravity flow analysis
- Capillary action assessment
Deliverables
- Detailed pathway maps
- Migration route documentation
- Material impact assessment
Saturation Level Analysis
Quantitative analysis of moisture saturation levels in affected materials
Activities
- Material-specific moisture measurement
- Saturation level calculation
- Drying potential assessment
- Timeline estimation
Deliverables
- Saturation level maps
- Material condition reports
- Drying projections
Comprehensive Reporting
Detailed documentation of findings, analysis, and recommendations
Activities
- Technical report preparation
- Visual documentation compilation
- Repair recommendation development
- Priority ranking system
Deliverables
- Comprehensive technical report
- Visual documentation package
- Repair specifications
Benefits of Professional Water Ingress Mapping
Ready for Professional Water Ingress Mapping?
Get comprehensive moisture analysis and water pathway mapping from BC's leading specialists.